PRODUCTS HOT
Centrifuge cairt gel Plasma 12/24 Buidheann fala a’ taipeadh Id seròlach
| Tagraidhean: | ●ABO blood type test test ●Rh blood group antigen test ●Irregular antibody screening ●Cross match |
●HDN detection ●Platelet antibody screening ●Platelet crossmatch |
| Max.Speed | 3500rf | |
| Max.RCF | 1554 xg | |
| Max.Capacity | 24 cairt | |
| Rotors co-ionnan | Disk card rotors | |
| taisbeanaidh | LCD | |
| Modail Àireamh: | XK-12B | |
| teisteanais: | CE, ISO13485, ISO9001: 2015 | |
| Bharantais | Barantas 1 bliadhna airson an inneal gu lèir, 3 bliadhna barantas airson an compressor agus 5 bliadhna barantas airson an motair. Pàirtean ùra an-asgaidh agus luingearachd taobh a-staigh barantas. | |
- Tuairisgeul
- Video
- Mion-chomharrachadh teicnigeach
- Rotors agus Accessories
- Buannachd farpaiseach
Micro column gel technology is extensively employed in blood serology, routine serum detection, red blood cell washing, microcolumn gel immunoassay experiments, and other applications due to its standardized operation and sensitive testing capabilities. The XK-12B blood gel card desktop low-speed centrifuge with a 12/24 card rotor meets the standard operation requirements for batch processing. The system features microcomputer control and automatic imbalance detection technology, ensuring easy operation and precise detection results. This instrument is essential for experimental hematology in hospitals and blood banks.
Principle for Blood Gel Card(ID-Card) Centrifuge
The principle behind the Blood Gel Card Centrifuge is based on the microcolumn gel immunoreaction, specifically the red blood cell agglutination test, also known as microcolumn gel hemagglutination assay (MGHA). Within the microcolumn gel tube, the red blood cells and their corresponding antibodies combine to form a clump of red blood cells. Through low-speed centrifugation, the clot is positioned either on the surface or within the gel, while the red blood cells that are not bound to the antibody settle at the bottom of the tube (the tip of the tube bottom).
buannachdan
The advantages of Micro Column Gel Technology include its simplicity of operation, lack of washing and confirmation tests for negative results, which solves the problem of the Coombs test being difficult to routinely apply in clinical practice due to its complexity and time-consuming nature. It also promotes the incomplete antibody detection theory to become the clinical "gold standard". The system can process multiple specimens at once (12/24 cards), enabling the detection of a large number of clinical specimens. Additionally, it offers advantages such as accuracy, sensitivity, minimal specimen consumption, long-term storage of results, easy standardization, and safer operation.
Paternity Testing Method
The Paternity Testing Method involves the use of ABO blood type positive and negative type and RhD blood type test cards to detect human ABO and RhD antigens. The column agglutination method (microcolumn gel method) is a commonly used immunological method for blood group identification, in which red blood cell antigens and corresponding antibodies agglutinate in a microcolumn gel medium. This method is standardized and quantified, ensuring the accuracy of the results.
The following steps are involved in the process:
1.Blood sample collection (note: samples containing abnormally increased serum protein should be washed sufficiently before use).
2. Blood sample processing:
(i) Centrifuge the anticoagulated whole blood sample at 900~1000g centrifugal force for 5 minutes, the lower layer is the concentrated packed red blood cells with a concentration of about 80%. Carefully absorb the upper plasma in another test tube, which can be used directly in the experiment.
(ii) Dilute the packed red blood cells to be tested: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots. (iii) Dilute the red blood cells: Take 8-10μl packed red blood cells and add 1ml red blood cell diluent. The appearance should be a uniform light red with no flocs or blood clots.
3. Blood type card operation:
1) Mark the prepared micro-living gel reagent card.
2) Add the prepared red blood cell suspension to the first to fourth tubes respectively, and add the diluted inverted red blood cells to the fifth to sixth tubes.
3) Immediately centrifuge for 5 minutes (900rpm for 2 minutes, 1500rpm for 3 minutes) in a blood type card centrifuge, and take out the result of the naked eye judgment.
Design
● Microprocessor control with Brushless Motor. Accurate speed control.
● Easy operation. Colorful digital screen indicates all running parameters. Automatic lid -open alarm when the instrument is off.
● Professional programming design. No need for manual setting. Just run it.

Feumar JavaScript airson a chluich
● Glasadh mullach fèin-ghluasadach agus cumail suas rè ruith rotor.
● Self-diagnostic system with high-strength chamber-coating and protective.
● "Mute" peutant teicneòlas, obrachadh astar as àirde a tha nas lugha na 50 decibeil.
● Tionndadh rpm / rcf fèin-ghluasadach.

sàbhailteachd
● Riochdaichte a rèir riaghailtean sàbhailteachd eadar-nàiseanta (me IEC 61010).
● Sàbhailteachd Eadar-ghlas mullach dealain, chan urrainn don doras fosgladh nuair a bhios an rotor a’ ruith agus cha ruith an inneal nuair a dh’ fhosglas am mullach agus nuair a nochdas còd mearachd.
● Sgaoileadh glas-glasaidh èiginneach nuair a dh'fhàillig cumhachd (glè fheumail ann an casg cumhachd ris nach robh dùil).
● Bithear a’ dèanamh dìonan sàbhailteachd airson cus astar gus dèanamh cinnteach à sàbhailteachd inneal an duine.

| Raon astair (rpm) | 0-3500rpm comasach air atharrachadh | Fuaim (dBA) | ≦50 dB(A) |
| Comas as motha (ml) | 24 cards | Tomhas (mm) | 430*320*250mm(12 cards) 440*400*230mm(24 cards) |
| Raon RCF (xg) | 0-1554xg a ghabhas atharrachadh | cuideam lom | 13 KG (with 12 cards) 22KG (with 24 cards) |
| cumhachd | AC220V,50HZ,5A,60W | ||
| Chan eil. | Notaichean | comas | Astar rothlach | Max.RCF | Time | Nota |
|
NO.1
|
Pre-centrifuge program group | 12 cairt | 3500r / min | 1232xg | 1 mhionaid | Program group can be set for different blood type cards. |
|
NO.2
|
Test program group | 12 cairt | 900r / min | 81xg | 2 mionaid | |
| 1500r / min | 226xg | 3 mionaid | ||||
|
NO.1
|
Pre-centrifuge program group | 24 cairt | 3500r / min | 1554xg | 1 mhionaid | |
|
NO.2
|
Test program group | 24 cairt | 800r / min | 81xg | 2 mionaid | |
| 1335r / min | 226xg | 3 mionaid | ||||
![]() | ||||||
1.Professional centrifuge saothraiche, prìs fharpaisich.
2.ISO9001, ISO13485, CE, Teisteanas SFDA, bidh a h-uile inneal fo dheuchainn càileachd teann agus pacadh math mus tèid a ghiùlan.
3.Long-ùine taic theicnigeach agus proifeiseanta seirbheis luchd-cleachdaidh aig a h-uile ìre den toradh reic, lìbhrigeadh agus operation.Our sgioba seirbheis làn teisteanais agus eòlach a 'toirt dhut le ìre shònraichte de thaic airson do cheannach airson a bheatha gu lèir.
4.We urrainn cuideachd a 'tabhann gnàthaichte fuasglaidhean airson luchd-dèiligidh' riatanasan sònraichte.
5.Powered le sgioba èifeachdach de innleadairean le taic bho bhliadhnaichean de eòlas anns na raointean aca fhèin, tha a 'chompanaidh a' dèanamh cinnteach gu bheil gach toradh a dh'fhàgas an aonad saothrachaidh suas ris a 'chomharra anns a h-uile dòigh.